Specification :-
Anesthesia Machine, designed with state-of-the-art technologies, is one of high utility with excellent performance and complete functions.
Main body is made of High-strength engineering plastic rack, light,beautiful and corrosion resistant
It can be applied on both Adult & Child
Gas source O2: 0.28~0.6MPa N2O: 0.28~0.6MPa
Flow meter O2: 0.05~10L/min N2O: 0.05~10L/min
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply25~75L/min
Vaporizer Among Halothane, Enflurane, Isoflurane and Sevoflurane,any one can be chosen for application as required by the customer. The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate.
Reliable pneumatic transmission system.
Modularized design and upgrading is available.
Low oxygen pressure alarm : There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Low oxygen pressure alarm. There will be sound alarm when the oxygen pressure<0.2Mpa
Respiratory circuit has working mode: all-close, semi-close, semi-open APL≤12.5kpa
Respiratory bellows is supplied for adults and children
Tidal volume range:0~1500 ml
The Ventilator adopts microcomputer control with high-definition 5.7” LCD display,integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
Ventilation mode IPPV,SIPPV,SIMV, MANUAL
Ventilation function PEEP,SIGH, IRV
Ventilation parametersTidal volume 50~1500ml
Rate 2~99bmp
SIMV rate 2~20bpm
I:E 2:1~1:8
Inspiratory trigger pressure-10 ~20 cmH2O
PEEP 2~20 cmH2O
Pressure limitation10~60cmH2O
SIGH 1.5 times the inspiratory time
Parameters for ventilation monitoring tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway,pressure – time waveform, flow rate – time waveform, PEEP, inspiratory trigger pressure,(average pressure, oxygen concentration, battery capacity)
Security Alarm System
Oxygen concentration alarm : upper limit setting range (21%~99%),
Low limit setting range (18%~80%)
Airway pressure alarmupper limit setting range 5~60 cm H2O, Low limit setting range 0~50 cmH2O
Minute ventilation volume alarm upper limit setting range 1~20 L/min, Low limit setting range 0~19L/min
Tidal volumeupper limit setting range 100~1500ml, Low limit setting range 0~1400ml
Sustained high-pressure alarmit will give alarm when stress have consistently been higher than 2.5cm H2O
(Suffocation alarm, Power alarm, Intubation off alarm, battery voltage alarm)
Power AC 220V 50Hz